Sign In | Join Free | My wneducation.com |
|
Brand Name : GFUVE
Model Number : GF312B
Certification : CNAS
Place of Origin : CHINA
MOQ : 1set
Price : 9858
Payment Terms : T/T, L/C, D/A, D/P, Western Union, MoneyGram
Supply Ability : 5SETs/week
Delivery Time : 7 days
Packaging Details : Wooden package
Accuracy class : 0.05%,0.1%,0.2%
Power supply : 220V±10% or 110V±10%,50/60Hz
Voltage test range : 0-600V
Current test range : 20mA-20A(with CT 10mA-3000A)
Phase angle : 0°~360°
Power factor : -1~0~+1
Pulse : input & output
Display : 6"TFT
Communication port : RS232
Connection : 1P2W 1P3W 3P3W 3P4W
Product name : portable energy meter calibrator
GF312B Onsite portable energy meter calibrator standard reference meter with current clamp
GF312B portable three phase watt meter calibrator with printer is used to calibrate three phase, single phase, active and reactive watt meters. And it also can be used as voltage, current and power meter to measure AC parameters of three phase power line.It can measure wave distortion factor and 2nd to 63th harmonic wave.
Multi Functional Electrical Calibration Equipment 0.05%RG Adjustment Fineness. Calibration Of Three Phase Energy Meter. Programmable Calibration Of Three Phase Energy Meter Standard Power Source. 3 Phase AC Current Calibrator / Kwh Meter Multi Tester Calibration Device. High Precision Calibration Of Three Phase Energy Meter With LED Display
Features
Parameters
Electrical parameters | |
---|---|
Accuracy | 0.05%, 0.1%, 0.2% |
Power supply | 220V ± 10% or 110V ± 10%, 50/60Hz ± 2Hz |
Test Voltage | |
Range | 0V-600V |
Error | ±0.05% (30V-600V) ±0.1% (5V-30V) |
Harmonic | 2nd-63st |
Test Current | |
Range (direct connection) | 20mA-20A |
Error (direct connection) | ±0.05% (100mA-20A) ±0.1% (20mA-100mA) |
Range (Clamp CT) | 10mA-3000A |
Error (Clamp CT) | ±0.2% (100mA-3000A) ±0.5% (10mA-100mA) |
Harmonic | 2nd-63st |
Power measure error | |
Active power (direct connection) | ±0.05% (0.1A-20A) ±0.1% (0.02A-0.1A) |
Reactive power (direct connection) | ±0.1% (0.1A-20A) |
Energy measure error | |
Active energy (direct connection) | ±0.05% (0.1A-20A) ±0.1% (0.02A-0.1A) |
Reactive energy (direct connection) | ±0.1% (0.1A-20A) |
Phase angle | |
Range | 0° ~ 360° |
Resolution | 0.01° |
Error | ±0.05° |
Frequency | |
Range | 45Hz-65Hz |
Resolution | 0.001Hz |
Accuracy | 0.005Hz |
Power factor | |
Range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Error | 0. 0005 |
Pulse output | |
Energy constant | 180000imp/kWh, 1800imp/kWh, 18imp/kWh |
Pulse ratio | 1:1 |
Output level | 5V |
Pulse input | |
Input channel | 1 |
Input level | 5-24V |
Input frequency | Max. 2MHz |
Display | |
Resolution | 6”TFT (640×480) |
Function | |
Vector diagram | Yes |
Waveform | Yes |
Energy accumulation | Yes |
Communication port | RS232 |
Communication with PC | Yes |
Mechanical parameters | |
Dimensions (W×H×D) (mm) | 390×200×160 |
Host Weight (mm) | 3 |
Weight (including Accessories 3pcs 100A clamp CT) (kg) | 12 |
Environmental conditions | |
Ambient temperature | -10°C to 40°C |
Relative humidity | 30%-85% |
Photo
![]() |
Onsite Portable Test Meter Calibration Standard Reference Meter With Current Clamp Images |